Alerts

Every alert tells you what to try first.

Humidity Alert

47 minutes ago

ACTIVE

Humidity has remained above 70% for 47 minutes.

Current

73%

Target

Below 62%

POSSIBLE CONCERNS

  • • Reduced transpiration
  • • Condensation
  • • Higher fungal disease pressure

TRY THIS FIRST

Increase dehumidification.

IF CONDITIONS DO NOT IMPROVE

  • • Increase exhaust.
  • • Check whether AC is cycling off.
  • • Check for standing water or excessive runoff.

Rising EC Warning

6 hours ago

ACTIVE

Root-zone EC has increased every day for the last 3 days (2.3 → 2.9 mS/cm).

Current

2.9 mS/cm

Target

2.0–2.6 mS/cm

POSSIBLE CONCERNS

  • • Reduced water uptake
  • • Possible tip burn
  • • Dryback slowing

TRY THIS FIRST

Increase irrigation volume slightly so you see 10–15% runoff.

IF CONDITIONS DO NOT IMPROVE

  • • Check runoff EC against feed EC.
  • • Reduce feed EC by 0.2 for one cycle.
  • • Verify sensor placement is not near a dripper.

Night Temperature Dip

Yesterday, 3:40 AM

RESOLVED

Lights-off temperature reached 64°F, 6°F below your usual night floor.

Current

Resolved at 68°F

Target

Above 68°F

POSSIBLE CONCERNS

  • • Wide day/night swing
  • • Slower nutrient uptake

TRY THIS FIRST

Confirm your heater or AC setpoint for lights-off.

IF CONDITIONS DO NOT IMPROVE

  • • Check for outside air infiltration overnight.

Pattern detection

Trends Phantom noticed over time

Night Humidity Spike

Humidity increased approximately 14% after lights-off for four consecutive nights.

WATCH

Dryback Slowing

Substrate previously reached 35% moisture around 4 PM. It now reaches that level around 8 PM.

WATCH

EC Accumulation

Root-zone EC has increased every day for five days.

WATCH

Sensor Health

All connected sensors are reporting fresh, varying values.

OK